Home / HFE fluids
Hydrofluoroethers
HFE fluids for cleaning, cooling and cells
Four hydrofluoroethers with boiling points from 56 to 93 °C. Low viscosity, low surface tension and zero ozone depletion.
- Boiling range
- 56–93 °C
- Ozone depletion
- ODP 0
- Purity, KL-H56 / H93
- ≥ 99.9%
- Water, KL-H56 / H93
- ≤ 20 ppm
Choose by boiling point
KL-H56
56 °CCAS 406-78-0 · same molecule as Asahiklin™ AE-3000
No flash point, 99.9% purity and 20 ppm water. Diluent for lithium battery electrolytes, PFPE lubricants and anti-fingerprint coatings.
View specifications
KL-H61
61 °CCAS 163702-07-6 · same molecule as Novec™ 7100
The workhorse for vapor degreasing, coating deposition and two-phase immersion cooling.
KL-H76
76 °CCAS 163702-05-4 · same molecule as Novec™ 7200
Higher boiling point for longer bath life in cleaning and for heat transfer loops.
KL-H93
93 °CCAS 16627-68-2 · same molecule as TTE
No flash point, 99.9% purity. Co-solvent and diluent for high-voltage and lithium-metal electrolytes.
Which HFE for which job
A filled mark shows the main use of each fluid. Ask us about anything not listed.
| Application | KL-H61 | KL-H76 | KL-H56 | KL-H93 |
|---|---|---|---|---|
| Precision cleaning and vapor degreasing | ● | ● | ● | – |
| Two-phase immersion cooling | ● | – | – | – |
| Heat transfer and chip test | ● | ● | – | – |
| Lithium battery electrolyte diluent | – | – | ● | ● |
| Lubricant and coating carrier | ● | – | ● | – |
Packaging
20 L and 200 L PE-lined steel drums. Samples from 500 g. Ask about ISO tanks for volume contracts.
Documents
TDS and GHS safety data sheet for each grade, batch COA with every shipment, transport classification on request.
Switching from Novec™
Send your current TDS and process conditions. We return a side-by-side comparison and a test sample.
Test an HFE in your process